Don't panic when the pressure sensor breaks down

Author:Browse:1564文章來源:www.mbpc8.comTime:2020-07-22

Intro:

Don't panic when the pressure sensor fails. Try to solve it. If the pressure rises, the transmitter output does not rise In this case, first check whether the pressure sensor pressure interface leakage or blockage; If not, check connection mode and power supply; If the power supply is normal, just pressurize to see if the output has changed, or check

Don't panic when the pressure sensor fails. Try to solve it.

If the pressure rises, the transmitter output does not rise

In this case, first check whether the pressure sensor pressure interface leakage or blockage; If not, check connection mode and power supply; If the power supply is normal, just pressurize to see if the output has changed, or check whether the sensor zero has output; If there is no change, the sensor is damaged, which may be due to instrument damage or other parts of the system.

Problems with pressure sensor seals

The pressure transmitter output does not change, then the pressure transmitter output changes suddenly, the pressure release transmitter zero can not go back, this may be the pressure sensor sealing ring problem.

The contrast between the transmitter and the pointer pressure gauge is quite wide

Pressure sensor

Deviation is a normal phenomenon, just confirm the normal range of deviation; The final fault is the influence of the mounting position of the differential pressure transmitter on the zero output. Due to the small measuring range of the differential pressure transmitter, the sensor elements in the transmitter will affect the output of the differential pressure transmitter.

The transmitter output signal is unstable

The problem with this failure is that it is a source of pressure. The pressure source itself is an unstable pressure, which may be due to the weak anti-interference ability of the instrument or the pressure sensor, the serious vibration of the sensor itself, and the failure of the sensor.

Under normal circumstances, due to the different specifications of the sealing ring, the sealing ring will be pressed into the pressure inlet of the sensor after tightening, blocking the sensor. The pressure medium cannot enter the sensor when pressurizing, but when the pressure is high, the sealing ring will suddenly open, and the pressure sensor will change due to the pressure. The best way to eliminate this failure is to remove the sensor and directly check that zero is normal. If zero is normal, replace the seal ring and try again.

During installation, the pressure sensitive part of the transmitter should be perpendicular to the axial direction of gravity. After installation and fixation, the zero of the transmitter should be adjusted to the standard value.